Regio Med

Aparate produse sanguine

Loading...

Banca sange

Model: WKA63-180V

DESCRIPTION:

  • With glass door
  • It is mainly used in laboratories, operating rooms, transfusion centers, emergency rooms and in hospital laboratories.
  • The cooling system is made with hermetic compressor, with condensed air, very quiet, with HFC refrigerant
  • Automatic defrosting with condensed water evaporation
  • The interior is made of white painted steel
  • The exterior of the refrigerator is made of white painted steel
  • The solid access door is provided with a micro-contact, which blocks the ventilation when the door remains open.
  • Sealing is done with a silicone gasket, easy to clean
  • Cooling is achieved by recirculating the blowing air, which allows a temperature distribution, achieving temperature uniformity
  • Insulation made with resin sponge with a thickness of 45 mm

 

Control system

  • Alphanumeric LCD display, illuminated, with two lines and 16 characters
  • Taste cu membrana, comutator I/O, tasta functionala Menu cu ”+/-”, taste care permit selectarea valorilor parametrilor si functiilor
  • Securitatea utilizatorului, cu parola, pentru controlul accesului persoanelor neautorizate
  • Monitorizare cu 2 canale, permite ajustatarea valorilor medii de la doua RTD Pt 100 senzori; la avaria unui senzor, se comuta pe altul.
  • Senzorii pot fi configurati F/W, in diferite moduri, in functie de necesitatile utilizatorului.
  • Pragul si alarma se pot configura cu o acuratete de 0,1° C

 

Control de siguranta

  • In cazul unor avarii, se va stabiliza temeperatura, compresorul continuand sa functioneze in acelasi mod ca si inainte de avariei

 

Recuperare de urgenta

  • In cazul defectarii unitatii centrale, congelatorul opereaza ca si inainte de eveniment

 

Monitorizarea alarmelor

  • The end user is allowed to permanently know the status of the device as well as its content
  • Alarm with noise and flashing light
  • Alarm for low / high internal temperature
  • High pressure alarm
  • Battery error alarm
  • Battery alarm
  • Alarm door open
  • Adjustment fault sensor
  • System failure sensor
  • Dirty capacitor damage
  • Compressor time failure

 

Technical data:

  • Capacity of  150 L
  • With one door
  • Supply voltage: 220-240 V, 50-60 Hz
  • Temperature range: 0 – 10 ° C
  • Weight  55 Kg

Dimensions: 61 W x 62 D x 104 H cm

 

Accessories not included in the price:

  • Paper disc recorder, with weekly cycle
  • Paper discs, 100 pieces

Alte produse recomandate