ATLAN 350 Anaesthesia Machine with Sevoflurane Vaporiser and Bronchial Aspirator
- Ask for details on 0724 175 996
- ATLAN 350 ANAESTHESIA MACHINE WITH VAPORISER FOR SEVOFLURANE, BRONCHIAL ASPIRATOR
- Atlan 350 base unit
- Ventilation modes VC, VC-SIMV, PC, PC-SIMV, CPAP /PSV
- Anaesthetic gas and CO2 analyser
- 3-gas mixer
- 3 m gas supply hose
- Mounting system for 1 vaporiser
- Accessories: flow sensor, single-use patient tubing, anaesthetic filter, neonatal option
- Bronchial aspirator – air-driven
Sevoflurane vaporiser
- Vapor 3000 Sevoflurane
Dräger Vista120 Model C patient monitor (15″ touch screen, ECG, SpO2, NIBP, Temp) MS32996:
| • Vista 120 S monitor |
| • Li-Ion battery |
| • 3-lead ECG cable – adult |
| • SpO2 sensor – adult |
| • 3 m NIBP hose |
| • ECG electrodes – adult |
| • Temperature sensor – adult |
| • NIBP cuff, size M |
| • Printer |
DESCRIPTION:
- General anaesthesia machine that can be used for all patient categories (adults, children, newborns)
- Base unit on a mobile chassis with an inlet block for the O2, air and N2O supply and an electronic block with flowmeters for dosing these gases
- Mobile chassis: antistatic, with wheels fitted with a central brake, integrated drawer, work surface / writing shelf, variable-intensity lighting for the writing shelf, vertically mounted rails on both sides of the machine for fixing additional devices
- Secretion aspirator: active suction with compressed air, fixed on the machine chassis, integrated module for measuring O2, CO2, N2O and anaesthetic gases
Gas dosing unit for O2, Air, N2O
- The flow of medical gases is adjusted from the touch screen of the anaesthesia machine; the fresh gas range setting is a minimum of 0.2-15 L/min; electronic measurement of the fresh gas flow: 0-15 L/min with an accuracy of 10%.
- Medical gas flows are also displayed as columns on the screen of the anaesthesia machine, simultaneously with the display of the ventilation parameters
- Electronic control of fresh gas delivery, for O2 – N2O or O2 – air mixture. Automatically ensures a minimum concentration of 25 % O2 in the O2 + N2O mixture
- By-pass control (of the vaporisers) for emergency administration of O2 into the circuit
- Rotary oxygen administration knob (even with the equipment switched off) with the possibility of adjusting the flow in the range 2-10 L/min
Patient breathing circuit
- Semi-closed system type with fresh gas decoupling, including flow sensors • Soda lime canister, adult corrugated tube circuit.
- Space for the Y-piece
- Electric heating system integrated into the machine to prevent condensation
- Bypass for the overpressure safety valve for Manual/Spontaneous
Anaesthesia machine ventilator
- Electric ventilator
- The equipment can ventilate with ambient air, delivering the set VT even when all gas sources have failed
- Adjustable ventilation parameters (minimum ranges)
- Tidal volume: 10 – 1500 mL
- PEEP: 0 and 2 – 35 mbar (cmH2O)
- Frequency: 3 – 100 bpm
- I:E ratio from 50 : 1 to 1 : 50
- Inspiratory flow: 0.1-120 L/min
- Pressure rise time (slope) 0 – 2 sec.
- Inspiratory time 0.2 – 10 sec
- Trigger sensitivity 0.3 – 15 L/min
- Inspiration termination criterion 5 – 80 %
- Ratio of plateau time to inspiratory time 0 – 60%
- Pressure support above PEEP: off, 3 – 80 mbar
- Pressure limitation between PEEP + 10 and 80 mbar
- Inspiratory pressure between PEEP + 5 and 80 mbar
Ventilation modes:
- Manual
- Spontaneous
- Volume-controlled ventilation:
Compliance compensation
- VT is corrected by the determined compliance of the breathing hose, e.g. an additional volume is delivered to ensure the volume is applied to the patient.
- On the device variant with an integrated patient gas measurement module, the VT delivery is corrected by the amount of aspiration flow as soon as the CO2 breathing phases are detected.
- Volume-controlled, pressure-limited, time-controlled, machine-triggered, with constant inspiratory flow volume-controlled, pressure-limited, time-controlled, machine-triggered, with constant inspiratory flow synchronised with inspiration volume-controlled, pressure-limited, time-controlled, machine-triggered, with constant inspiratory flow
- Synchronised with inspiration, and at PEEP level during the expiratory phase it has pressure support with ΔPsupp outside the trigger window
- Automatic ventilation with self-adjusting flow: in the volume-controlled ventilation modes, the proprietary software will command the inspiratory flow to adapt automatically while guaranteeing delivery of the preset tidal volume at the lowest possible pressure, without pressure peaks
- Pressure-controlled ventilation:
- Pressure-controlled, time-controlled, machine-triggered; mandatory breaths are triggered by the machine and not by the patient.
- Pressure-controlled, time-controlled, synchronised with breathing.
- When synchronisation is on, breaths are adapted to the patient’s spontaneous respiratory efforts.
- If the patient’s spontaneous respiratory effort is detected during the inspiratory trigger window, a patient-triggered breath will be initiated.
- Pressure-controlled, time-controlled, synchronised with breathing, and at PEEP level during the expiratory phase it has pressure support with ΔPsupp outside the trigger window.
- Spontaneous breathing with continuous positive pressure (CPAP)
- Spontaneous breathing with continuous positive pressure and pressure support (CPAP/PS) • Apnoea ventilation
Respiratory monitoring:
- Inspiratory and expiratory respiratory volume, total minute volume, mandatory and spontaneous, airway pressure, peak inspiratory pressure, mean pressure, PEEP, total rate, mandatory and spontaneous, O2, CO2, N2O concentration, volatile anaesthetic agent, dynamic compliance, resistance and elastance
- The screen of the machine is a colour touch screen with a diagonal of at least 15.3″
- The monitor can display 4 curves simultaneously, or 3 curves and a row of boxes for parameters, which can be selected from the following: volume, pressure, flow, O2 concentration, CO2 concentration, volatile anaesthetic agent concentration
- The monitor can display short-term trends (minitrends) simultaneously with the three waveforms displayed in real time, or the volume – pressure loop
- The bar graph indicates whether the device is being supplied with a sufficient volume of fresh air
- The monitor can display the following parameters as column graphs:
- tidal volume
- minute volume
- The monitor can display trends over time graphically and in tabular form, with the possibility of enlarging the areas of interest, for the following parameters: O2 concentration, CO2 concentration, volatile anaesthetic agent concentration, N2O concentration, minute volume, lung compliance
- Self-test at start-up that checks and calibrates sensors and valves and detects leaks. Leak-detection assistance programme.
- The therapy buttons and controls are colour-coded in 5 colours according to availability, selection. Configurations can be exported and imported using a USB flash drive
- The monitor allows real-time measurement of lung compliance
- The monitor allows measurement of gas concentration on inspiration and expiration, and calibration is fully automatic, for the following gases:
- oxygen
- N2O
- volatile anaesthetic agents (Isoflurane, Sevoflurane, Desflurane) Automatically recognises the type of volatile anaesthetic agent
- Automatically recognises the mixture of anaesthetic agents and allows quantitative measurement of 2 anaesthetic agents from the gas mixture
- Calculates the minimum alveolar concentration according to age, taking into account several anaesthetic gases in the gas mixture and the N2O concentration.
- Displays the following types of dynamic relationship as loops:
– Pressure-Volume,
– Flow-Volume
- Graphically displays, as a column, the type of fresh gas flow setting: too low, efficient or excessive.
- Permanently displays a graphic column indicating the efficiency of fresh gas use
- Displays a stopwatch with start/stop option
- The low-flow configurator displays the bar graphs for the low fresh gas flow and the total flow.
- Both bar graphs are on the same scale.
- Automatic leak compensation
Audible and visual alarm settings and limits
- Alarms for: patient disconnection, exceeding preset alarm values, operating errors, automatic setting of alarm limits
- Audible and visual alarms prioritised within the alarm levels, with active alarms displayed in order of priority
- Basic, configurable settings of the alarm limits for each specific ventilation mode; button (control) to silence audible alarms for 2 minutes with display of the remaining time
- Option to save various screen configurations (position of the curves on the screen, type of curves, etc.) to be loaded later
General features
- Self-test at start-up
- Automatic execution of the compliance and circuit leak test
- Display of the efficiency of the fresh gas setting
- Display of gas and anaesthetic agent consumption, anaesthetic agent and O2 uptake. Display of MV×CO2 with trend
- Anaesthetic gas compensation function
- The CBM mode allows patient monitoring without unnecessary alarms, including during extracorporeal oxygenation of the patient by means of a heart-lung machine.
- System configuration for adult, child, newborn patients, with start-up and alarm values set for each patient group
- Option to adjust the alarm volume
- Automatic setting of alarm levels
- Displays errors of the system, sensors, breathing system, gas supply, electrical power supply, ventilator, concentration sensor, connections, leaks, pressure level, internal temperature level, etc.
- The breathing system is autoclavable and requires no tools for disassembly
- The device supports the following remote service functions:
- Support note
- Remote device check
- Interactive call
Power supplies:
- Oxygen, Air, N2O at working pressure: 3-6 bar
- In the absence of oxygen and compressed air, the anaesthesia machine ventilates the patient with ambient air
- Battery: minimum 45 minutes Alarm log
- The device can capture and store, among others:
– Measured values
- Setting values and associated changes
- Patient data
- Ventilation modes
- Events (alarms, acknowledged alarms, start time and stop time)
- Test results
- Gas consumption
- Anaesthetic agent consumption
- Allows the screen contents, trends and data to be exported to a USB storage device.
- Screenshots
- Network connection option; connections: LAN, USB, COM
Integrated vaporiser for Sevoflurane
- Adjustable concentration in the range 0.2 – 8%
- Adjustable flow in the minimum range: 0.2 – 14 L/min
- Minimum filling volume: 300 ml
- Can be transported in any position without risk of losing anaesthetic agent
- Requires no subsequent calibration
| Vital signs monitor and capnography | ||||||||
| ECG | ||||||||
| – can monitor 5 ECG leads using a 5-wire cable | ||||||||
| – display of two or five leads at the same time on the main screen | ||||||||
| – real-time waveform display with a selectable sweep speed of 6.25-12.5 – 25 – 50 mm/sec | ||||||||
| – option to display the 5 ECG leads on half of the screen simultaneously with the other parameters
monitored on the other half of the screen |
||||||||
| – adult pulse measuring range (15 – 300 beats/min) | ||||||||
| – paediatric and neonatal pulse measuring range (15 – 350 beats/min) | ||||||||
|
Respiration |
||||||||
| – adult respiration measuring range (0 – 120 resp/min) | ||||||||
| – paediatric and neonatal respiration measuring range (0 – 150 resp/min) | ||||||||
| – display of the respirogram curve | ||||||||
|
SpO2 pulse oximetry |
||||||||
| – range 0 – 100% | ||||||||
| – display of the plethysmogram curve | ||||||||
| – pulse measuring range (25-300 beats/min) | ||||||||
| – adjustable volume for the peripheral pulse, can be switched off | ||||||||
|
Non-invasive blood pressure |
||||||||
| – oscillometric measurement method | ||||||||
| – systolic, diastolic and mean pressure values displayed on the main screen at the same time, with a resolution of 1 mmHg and a cuff pressure measuring range: 0-300 mmHg
– measurement protection: adult: 297 ±3 mmHg, child: 245 ±3 mmHg, newborn: 147 ±3 mmHg |
||||||||
| – single key on the front panel of the monitor to start a measurement
– maximum measurement period is 120 s for adults/children and 90 s for newborns |
||||||||
| – adjustable time intervals for taking measurements | ||||||||
| – continuous NIBP measurement (5 min.) in emergencies | ||||||||
| – recording of 1,200 measurements | ||||||||
|
Temperature |
||||||||
| – absolute temperature measuring range (0 – 50 °C) | ||||||||
| General features: | ||||||||
| – The monitor has a 15″ colour touch screen | ||||||||
| – The parameters can be controlled by touching the screen (touch screen) | ||||||||
| – The touch screen can be calibrated by the user | ||||||||
| – Additionally, the parameters can be controlled by means of a rotary knob | ||||||||
| – The layout of the parameters on the screen can be configured by the user: | ||||||||
| – the position of each monitored parameter on the screen is selectable
– the colour of the waveforms is selectable – the user can choose from a series of pre-configured screens for the different hospital departments (ICU, operating theatre, etc.) |
||||||||
| – Alarm levels are displayed together with the parameter values on the main screen | ||||||||
| – The alarm levels can be adjusted manually | ||||||||
| – The monitor signals alarms visually and optically if the preset parameter values are exceeded, according to their priority. | ||||||||
| – The alarm can be silenced for a set period of time | ||||||||
| – Battery operation for 2 hours | ||||||||
| – Graphic indicator for the battery charge level | ||||||||
| – Single key on the front panel of the monitor to silence alarms | ||||||||
| – Single key on the front panel of the monitor to return to the main menu | ||||||||
| – The monitor allows the operating mode to be selected according to the patient type (adult, paediatric, newborn) | ||||||||
| – The monitor has a simulation / demo mode for staff training | ||||||||
| – The monitor can store the evolution of the parameters over time (trends) for the last 240 hours. These
can be viewed both as a graph and as a table |
||||||||
| The monitor can store 60 events including parameters and waveforms
– The monitor recognises 16 types of arrhythmia including: Asystole, ventricular fibrillation, artefact, ventricular tachycardia, couplet, bigeminy, trigeminy, bradycardia, R on T, PVC, BRADY, MISSED BEATS, IRR, PNC, PNP, VBRADY, VENT
– The monitor is equipped with an integrated thermal printer with the following features: – compatible with 48 mm wide paper rolls – paper speed adjustable between 25 mm/s and 50 mm/s – printing of 3 waveforms simultaneously – Printing modes: – 8 seconds in real time – automatic for 8 seconds – alarms – trends – drug calculations Monitoring of 3 invasive pressures (without accessories) The monitor can be upgraded – Cardiac output – BIS module
|
Consultancy
We offer personalised consultancy and support for medical projects, from equipment to integrated solutions.
Nationwide delivery
We deliver nationwide, directly to the customer's location, or you can collect from our distribution points.
SEAP public tenders
On request, we can list the products you need on the SEAP platform for public procurement.
Related products
No products were found matching your selection.