Model: WKA63-180V

DESCRIPTION:

With glass door
Mainly used in laboratories, operating theatres, transfusion centres, emergency rooms and hospital laboratories.
The cooling system is made with a very quiet, hermetic, air-condensed compressor with HFC refrigerant
Automatic defrosting with evaporation of condensate water
The interior is made of white-painted steel
The exterior of the refrigerator is made of white-painted steel
The solid access door is fitted with a micro-switch, which stops the ventilation when the door is left open.
Sealing is done with a silicone gasket, easy to clean
Cooling is achieved by recirculation of blown air, which allows temperature distribution and thus achieves temperature uniformity
Insulation made of resin foam, 45 mm thick.

Control system

Illuminated alphanumeric LCD display, with two lines and 16 characters
Membrane keys, I/O switch, Menu function key with “+/-”, keys that allow selection of parameter and function values
User security with password, to control access by unauthorised persons
2-channel monitoring, allows adjustment of the average values from two RTD Pt 100 sensors; if one sensor fails, it switches to the other.
The sensors can be configured via firmware (F/W), in different modes, depending on the user’s needs.
The threshold and alarm can be configured with an accuracy of 0.1° C.

Safety control

In the event of a failure, the temperature will stabilise, with the compressor continuing to run in the same way as before the failure.

Emergency recovery

If the central unit fails, the freezer operates as it did before the event.

Alarm monitoring

The end user is allowed to know the status of the device at all times, as well as its contents
Alarm with sound and flashing light
Low/high internal temperature alarm
High-pressure alarm
Battery fault alarm
Battery alarm
Door open alarm
Control sensor failure
System failure sensor
Dirty condenser damage
Compressor time failure

Technical data:

Capacity of 150 L
Single door
Supply voltage: 220-240 V, 50-60 Hz
Temperature range: 0 – 10 °C
Weight 55 kg

Dimensions: 61 width x 62 depth x 104 height cm

Accessories not included in the price:

Paper disc recorder, with weekly cycle
Paper discs, 100 pieces

Consultancy

We offer personalised consultancy and support for medical projects, from equipment to integrated solutions.

Nationwide delivery

We deliver nationwide, directly to the customer's location, or you can collect from our distribution points.

SEAP public tenders

On request, we can list the products you need on the SEAP platform for public procurement.

Related products