BS60 Automatic Biochemistry Analyser, Model BX103-BS60

Request a quote via WhatsApp ➔

Model: BX103-BS60

Automatic biochemistry analyser – BS60

Fully automated system for wet chemistry reagents, with random access – any combination of tests can be performed, patient by patient, from the worklist and in emergency mode.

Key features:

  • Capacity: 600 photometric tests / hour (without the ISE module)
  • ISE module speed: up to 225 tests / hour
  • Up to 78 tests performed simultaneously plus 3 ion tests
  • 8-step self-washing system
  • Bidirectional interface
  • STAT emergency test priority (at any time and in unlimited number)
  • Measurement principle: photometric absorbance, turbidimetry, potentiometry
  • ISE ion module with Na, K, Cl parameters
  • Sample types used: serum, plasma, urine
  • The biochemistry analyser is fully configured, with its own cuvette washing station
  • Methodology: end-point, end-point with blank, fixed-time, kinetic, with one, two, three, four reagents, monochromatic / bichromatic
  • The analyser ensures traceability of reagents, calibrators, controls and working methods
  • Programming: open system, defines the profile and calculates the chemistry

Range of tests performed:

  • Liver: ALT, AST, ALP, GGT, D Bil, T Bil, TP, ALB, TBA, PA, CHE, ADA, AFU, 5-NT
  • Renal: UREA, CREA, CREA Sarcosine, UA, CO2, Microalbumin, beta 2-MG, CysC
  • Electrolytes: Na, K, Cl, Li
  • Cardiac: CK, CK MB, LDH, HBDH, HCY, MYOGLOBIN
  • Iron: Fe, FER, TRF, TIBC / UIBC
  • Lipids: TC, TG, HDL-C, LDL-C, APOA1, APOB, LP (a), Lipase
  • Pancreatic: Alpha AMY, LIP, Pancreatic amylase, Acid phosphatase
  • Diabetes: GLU GOD POD, GLU HK, HbA1c, FUN
  • Inorganic ions: Ca, Mg, P
  • Rheumatism: hs-CRP, CRP, RF, ASO
  • Immune: IgA, IgG, IgM, IgE, C3, C4, CRP

 

Sample compartment:
• Sample positions: 90 positions for 5, 7, 10 ml primary tubes and sample cups. Built-in barcode reader for all sample positions.
• Sample volume: 1.5-45 µL in steps of 0.1µl
• Automatic liquid level detection (sample), blood clot detection, alert for haemolysed, icteric and lipaemic samples, anti-collision protection, vertical collision detection
• Warning of missing sample and of on-board sample validity
• Continuous loading of samples during the working session
• The sample needle is washed automatically, both inside and outside
• Sample dilution: automatic pre-dilution and post-dilution of samples
• Samples are diluted in the cuvette in the event of any abnormality – non-linear sample, insufficient serum, high concentration values, etc.
• Sample identification: with barcode reader
• Warns of missing sample and of on-board sample validity. The sample volume can be topped up while working

Reagent compartment:
• Automatic liquid level detection, automatic calculation of the remaining reagent volume and the number of tests available, collision protection
• The reagent needles are washed automatically, both inside and outside
• Reagent positions: 80 positions in the refrigerated compartment at 2-10 °C
• Reagent volume: 10-200 µL in steps of 0.50 µl
• 2 pipetting arms
• Reagent pre-heating before serum pipetting
• The analyser uses standard-type cuvettes for reagents
• If one of the reagent positions runs out of test reagent, the instrument will run the next test, returning to it once the missing reagent is added
• On-board reagent volume monitoring system. Alarm system for low volumes, expired reagents or missing reagents
• The instrument provides information on the number of tests that can be run with the reagent volume on board
• Built-in barcode reader for reagents

 

Reaction system:
• Reaction rotor: has a rotating space containing 124 cuvettes with automatic washing system (reusable)
• Cuvette: optical path length 5 mm
• Reaction volume: minimum 100 and maximum 300 µl
• Operating temperature: 37±0.1 ºC
• Mixing system: independent mixing by the 2 systems

 

Cuvette washing system:
• 8 cuvette self-washing steps
• 8 washing needles

 

Optical system:
• Light source: halogen-tungsten lamp
• Photometry: reverse optics, location for static photometric fibre
• Wavelengths (12): 340 nm, 380 nm, 412 nm, 450 nm, 505 nm, 546 nm, 570 nm, 605 nm, 660 nm, 700 nm, 740 nm, 800 nm
• Absorbance range: from 0 to 3.3 abs (10 mm conv.)
• Resolution: 0.0001 Abs

Optional – ISE module
• Parameters: Na, K, Cl, Li
• Sample type: serum, plasma, urine
• Sample volume used – serum and plasma: 70 µl, diluted urine: 140 µl
• Reagent pack Na/K/Cl
• Washing solutions + ion module control

 

Control and calibration:
• Calibration mode: One point linear, two point linear, multi-point linear, Logit-Log 4P, Logit-Log 5P, Exponential, Polynomial, Parabola, Spline
• Calibrations can be archived, so new calibrations can be compared with the measured data
• QC is a mandatory daily test, at least once a day
• Control software: Westgard multi-rule, cumulative sum check, twin plot
• 2 types of controls can be defined per test

Result printing and data management:
• Results can be printed automatically or on request, with the possibility of quick reporting
• Results can be printed on the system printer or on a network printer
• Provides statistical data on the number of tests / calibrations / controls / repeats / dilutions performed daily and at intervals

Operating unit:
• Operating system: Windows 8 64-BIT
• Interface: RS 232
• Network port
• USB / parallel port

 

Technical data:
• Power supply: AC 200V ± 10%, 50/60 ± 3 Hz
• Temperature: 15-30 ºC
• Humidity: 35-85%
• Weight: 300 kg
• Dimensions: 119 L x 116 W x 72 H cm

Consultancy

We offer personalised consultancy and support for medical projects, from equipment to integrated solutions.

Nationwide delivery

We deliver nationwide, directly to the customer's location, or you can collect from our distribution points.

SEAP public tenders

On request, we can list the products you need on the SEAP platform for public procurement.

Related products