Complete Exercise Testing System, Model INNO36 – Cardio PC / E
- Ask for details on 0724 175 996
Model: INNO36 – Cardio PC / E
Diagnostic system for treadmill and/or exercise bike
12-channel ECG for analysing resting or exercise conditions
Standard and customised exercise protocols
Flexible report content
Automatic control of the exercise bike and treadmill
Automatic or manual blood pressure measurement
Graphic display of the exercise process and measured parameters
Large screen and data recording
Reliable automatic measurement analysis functions
Heart rate dependent on ST measurement and analysis
Arrhythmia analysis
Real-time measurement of axis position, amplitude and time parameters of the
Cardio PC / E system services
Real-time monitoring of 3/6/12 channels
Digital baseline filter
Real-time measurement and analysis of parameters on the average curves: axis position, amplitude (P, Q, R, S, T, ST, J), time parameters (P, interval, interval, QR, interval, QRS, QT interval), heart rate calculation
Alarms: heart rate, ST level change, blood pressure level
Exercise graph: load level, HR, blood pressure, RPP, revolutions, ES, SVES, VES, QT interval
Display of the load in MET
Heart rate definition by age
Weber functional classification
Calculation of aerobic capacity decline
Built-in customisable storage with printed reports
Documentation of angina, medication intake and pre-examination medication
System components:
CardioPC diagnostic programme for resting and exercise ECG
Latest-generation CardioPC USH-12
Patient cable with electrodes
High-performance PC-based diagnostic system
Colour monitor
Large laser printer
Innobase software for the Windows database management system
Optional:
Automatic blood pressure measurement for the bicycle ergometer and/or treadmill
ECG cable electrode system
Technical data (with USBH-12 head)
• PC measurement interface: USB, optional Bluetooth
Amplifier: 12-channel
Frequency response: DC … 150 Hz
Input noise: <20μVpp
CMRR min 120dB (with filter)
DC tolerance: ± 320 mV DC
Pacemaker tolerance max. 700 mV / 2ms
Pacemaker detection: min. 2 mV / 0.5 ms max. 700 mV / 2 ms
Peak input impedance: 50 Mohm
Input signal range: ± 10 mV
A/D converter resolution: 22 bits, 50 kHz
• Filters: – 50/60 Hz noise filter
Muscle filter
Digital baseline filter
Patient cable: 10-lead
Safety class: I, according to EN60601-1
ECG according to EN60601-2-25
Defibrillator protection: Only with the defibrillator protection cable supplied by the manufacturer!
Consultancy
We offer personalised consultancy and support for medical projects, from equipment to integrated solutions.
Nationwide delivery
We deliver nationwide, directly to the customer's location, or you can collect from our distribution points.
SEAP public tenders
On request, we can list the products you need on the SEAP platform for public procurement.
Related products